Typ UHE
Variations: 16
Note: Product illustration may differ
The EWT-PAB cable protection conduits are made of specially modified polyamide 6.
The material is halogen, phosphor and cadmium-free. Due to its excellent fire protection properties and very low smoke emission, this product can be used in railway technology and for static applications with medium to high mechanical stress.
The EWT-PAB cable protection conduits consist of a two-part, slit conduit system and are characterised by the following advantages:
The cable protection conduits can be opened and closed again at any time.
Mounting of pre-assembled cables
Retrofitting or repair in mechanical and plant engineering
mod. polyamide PA 6
> 250 N According to IEC EN 61386 M25/P21 Testing at 23 °C Fitting SVT
-40 °C–120 °C short term 160 °C
C.I.T. R22 / R23 HL3 : 0.61 NF X 70-100-1/-2 600°C (1112 °F)
Ds (max.) R22 / R23 HL3 : 68 ISO 5659-2 (25 KW/m²)
LOI R22 / R23 HL3 : ≥ 32 % ISO 4589-2
acc. to UL94: V0 self-extinguishing
ASTM E 162
ASTM E 1354
ASTM E 662
Boeing BSS 7239
Boeing BSS 7242
Bombardier SMP 800-C
> 650 N 50 x 50 mm According to IEC EN 61386 M25/P21 Testing at 23 °C
> 1000 N 100 x 100 mm According to IEC EN 61386 M25/P21 Testing at 23 °C
Alcohol
Mineral oils
Greases
Fuels
According to IEC EN 61386
Cycles: > 1200 Cycles
Annex 6+8