Room integrity set type RAS
Note: Product illustration may differ
Product images
Product information
The RAS Room integrity set is used in conjunction with the KDL/C or KDL/D and KDL/H cable entry plates. Because the system can be split apart the RAS room integrity system can be completely retrofitted on the inside of the housing. The fire protection mat reacts at temperatures exceeding 160°C (320 °F) by expanding and thereby closing off the opening completely fire resistant.
Special benefits of the RAS room integrity system are:
Approved for railway technology (EN 45545-2 / 3x HL3 / NFPA 130)
Room integrity (firewall)
Completely splittable system
Quick and easy assembly
Properties
Material
Frame: Polyamide 6
Fire properties NFPA130
Fire properties EN45545
C.I.T. R22 / R23 HL3 : 0,44 EN 17084
Ds (max.) R22 / R23 HL3 : ≥ 32 % ISO 4589-2
LOI R22 / R23 HL3 : 59 ISO 5659-2
Product reviews