Room integrity set type RAS

Variations: 12

Note: Product illustration may differ

Product images
Product information

The RAS Room integrity set is used in conjunction with the KDL/C or KDL/D and KDL/H cable entry plates. Because the system can be split apart the RAS room integrity system can be completely retrofitted on the inside of the housing. The fire protection mat reacts at temperatures exceeding 160°C (320 °F) by expanding and thereby closing off the opening completely fire resistant.

Special benefits of the RAS room integrity system are:

Approved for railway technology (EN 45545-2 / 3x HL3 / NFPA 130)

Room integrity (firewall)

Completely splittable system

Quick and easy assembly

Properties
Room integrity set type RAS LABS free
Room integrity set type RAS UV-resistant
Room integrity set type RAS Railroad EU approval
Material
Material

Frame: Polyamide 6

Fire properties NFPA130
Fire properties NFPA130

Fire properties EN45545
Fire properties EN45545

C.I.T. R22 / R23 HL3 : 0,44 EN 17084

Ds (max.) R22 / R23 HL3 : ≥ 32 % ISO 4589-2

LOI R22 / R23 HL3 : 59 ISO 5659-2

With our configurator, our individual cable entry systems can be easily created online within a few minutes for a wide range of applications according to your requirements.